Skip to content
Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-100

SAFFIRE-III

Spacecraft Fire Experiment-III

PreventionSolid fuelIgniterX-extracted, not hand-checked

Where its tests sit

NASA's table for this investigation reports no oxygen value, so none of its 2 test rows can be placed on the chart of the evidence. This is itself a gap: the oxygen level of these tests is not in PSI.

Key facts

Oxygen tested
Not reported
Pressure tested
Not reported
Airflow tested
30 cm/s
Fuel phase
Solid fuel
Gravity
Microgravity
Platform
Cygnus resupply vehicle (after it deberthed from the ISS)
Hardware
Saffire III enclosure in Cygnus
Hardware family
Large-scale spacecraft firesSaffire enclosure on the Cygnus cargo vehicle, after it left the ISS
Sample / burner size
  • Sample Thickness: .33 cm
  • Sample Length: 94 cm
  • Sample Width: 40.6 cm

Objective

The investigation aims to determine how rapidly a large-scale fire grows in low gravity. It also investigates low-gravity flammability limits compared to normal-gravity material flammability screening tests.

Key findings

Results determine microgravity flammability limits for several spacecraft materials, help validate NASA's material selection criteria, and show how microgravity and limited oxygen affect flame size.

Earth applications

Studying fire in small, sealed environments like Cygnus benefits fire safety and prevention efforts on Earth, including inside mines, airplanes, or submarines.

Fuels and samples

  • SIBAL Fabric, 0.33 cm thick, 94 cm x 40.6 cm

Sensors and measurements

  • cameras
  • thermocouples
  • radiometers
  • solid state sensors
  • anemometer

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (1)

  • Direction · 2 values, e.g. Concurrent; Opposed

Same in every test (5)

  • Material · SIBAL Fabric
  • Sample Thickness · .33 cm
  • Sample Length · 94 cm
  • Sample Width · 40.6 cm
  • Air Flow · 30 cm/s

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#11 of 2459
0 · 15 · 20 · 14 · 10
Moon base / pressurized rover#10 of 2459
0 · 15 · 20 · 14 · 10
Spacesuit#3 of 2449
0 · 5 · 20 · 14 · 10

Test table (2 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published. Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Sample NumberMaterialSample ThicknessSample LengthSample WidthAir FlowDirectionCamera 1Camera 2
S1SIBAL Fabric.33 cm94 cm40.6 cm30 cm/sConcurrent S1C1S1C2
S2SIBAL Fabric.33 cm94 cm40.6 cm30 cm/sOpposedS2C1S2C2
Where this came from(source of every field)
FieldValueSource
psi_idPSI-100json:accession
acronymSAFFIRE-IIIjson:investigationAcronym
titleSpacecraft Fire Experiment-IIIjson:title
doi10.60555/040q-4h36json:doi
platformCygnus resupply vehicle (after it deberthed from the ISS)
override
json:approach - "The Saffire-III experiments were performed on the Orbital Science’s Cygnus resupply vehicle after it deberthed from the ISS."
hardwareSaffire III enclosure in Cygnusjson:experimentHardware
fuel_phasesolidrule:fuel_phase_seed
fuelsSIBAL Fabric, 0.33 cm thick, 94 cm x 40.6 cm
llm
S1, SIBAL Fabric, .33 cm, 94 cm, 40.6 cm, 30 cm/s, Concurrent , S1C1, S1C2
o2_percent_rangenull (not reported)csv:none
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_range30; 30
  • csv:PSI-100_Experimental table_SAFFIRE-3.csv:Air Flow
gravitymicrogravityrule:gravity_seed
pillarspreventionrule:pillar_seed
measurementscameras; thermocouples; radiometers; solid state sensors; anemometer
llm
Once the sample was ignited flame images were captured using two cameras.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
objective_summaryThe investigation aims to determine how rapidly a large-scale fire grows in low gravity. It also investigates low-gravity flammability limits compared to normal-gravity material flammability screening tests.
llm
(1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA’s normal gravity material flammability screening test.
key_findingsResults determine microgravity flammability limits for several spacecraft materials, help validate NASA's material selection criteria, and show how microgravity and limited oxygen affect flame size.
llm
Results determine microgravity flammability limits for several spacecraft materials, help to validate NASA’s material selection criteria, and how microgravity and limited oxygen affect flame size.
earth_applicationsStudying fire in small, sealed environments like Cygnus benefits fire safety and prevention efforts on Earth, including inside mines, airplanes, or submarines.
llm
Studying fire in small, sealed environments such as the Cygnus cargo supply vehicle benefits fire safety and prevention efforts on Earth, including inside mines, airplanes, or submarines.
tests2 rows
  • csv:PSI-100_Experimental table_SAFFIRE-3.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-100rule:psi_page