PSI-102
SAME
Smoke and Aerosol Measurement Experiment
Where its tests sit
NASA's table for this investigation reports no oxygen value, so none of its 4 test rows can be placed on the chart of the evidence. This is itself a gap: the oxygen level of these tests is not in PSI.
Key facts
- Oxygen tested
- Not reported
- Pressure tested
- Not reported
- Airflow tested
- 5–10 cm/s
- Fuel phase
- Solid fuel
- Gravity
- Microgravity
- Platform
- International Space Station (ISS)
- Hardware
- Comparitive Soot Diagnostic Hardware
- Hardware family
- Smoke & dust detectionSmoke-measurement instruments (the SAME instrument was reused by DAFT for dust)
- Sample / burner size
- Not reported
Objective
The investigation aimed to quantify liquid smoke droplet sizes in microgravity and relate droplet size distribution to smoke generation and transport conditions. It also sought to develop a numerical model predicting smoke droplet growth based on pyrolysis rate, vapor properties, and flow environment.
Key findings
Not reported in PSI text
Earth applications
Smoke detectors developed from the results can be used in extreme environments on Earth, such as submarines or underwater laboratories, saving lives through accurate smoke detection.
Fuels and samples
- Teflon
- Kapton
- Silicone Rubber
- Lampwick
- Dibutyl Phthalate
Sensors and measurements
- smoke detectors
- video cameras
- thermophoretic soot samplers
- Transmission Electron microscope (TEM)
How the tests differed
What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.
Varied between tests (3)
- Air Flow (cm/s) · 2 values, e.g. 5; 10
- Weight loss rate (mg/min) · 2 values, e.g. 2; 1
- Aging Duration (minutes) · 2 values, e.g. 1; 20
Same in every test (1)
- Sample Material · Teflon
Score in each scenario
Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.
| Scenario | Rank | Score | A · B · C · D · E |
|---|---|---|---|
| ISS cabin | #13 of 24 | 58 | |
| Moon base / pressurized rover | #12 of 24 | 58 | |
| Spacesuit | #5 of 24 | 48 |
Test table (4 rows)
Test rows from NASA's experimental-table CSV, every cell exactly as published (4 non-test rows set aside, see Data cleaning). Download as CSV · Compare with all tests in the Data Explorer
Experimental table
| Sample # | Sample Material | Air Flow (cm/s) | Weight loss rate (mg/min) | Aging Duration (minutes) |
|---|---|---|---|---|
| 1 | Teflon | 5 | 2 | 1 |
| 2 | Teflon | 5 | 1 | 1 |
| 3 | Teflon | 5 | 2 | 20 |
| 4 | Teflon | 10 | 2 | 1 |
Data cleaning
What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.
PSI-102_Experimental table_SAME.csv · 8 CSV rows → 4 test rows
Set aside (4)
- row 5 listed as 'same conditions' but no measurements reported5 | Kapton: same conditions as 1-4
- row 6 listed as 'same conditions' but no measurements reported6 | Silicone Rubber: same conditions as 1-4
- row 7 listed as 'same conditions' but no measurements reported7 | Lampwick: same conditions as 1-4
- row 8 listed as 'same conditions' but no measurements reported8 | Dibutyl Phthalate: same conditions as 1-4
Where this came from(source of every field)
| Field | Value | Source |
|---|---|---|
| psi_id | PSI-102 | json:accession |
| acronym | SAME | json:investigationAcronym |
| title | Smoke and Aerosol Measurement Experiment | json:title |
| doi | 10.60555/gd4k-8h62 | json:doi |
| platform | International Space Station (ISS) | json:flightProgram |
| hardware | Comparitive Soot Diagnostic Hardware | json:experimentHardware |
| fuel_phase | solid | overridejson:approach - "The measurements were made using smoke generated by overheated spacecraft materials" (samples in the SAME table: Kapton, Teflon, silicone rubber, lampwick; also dibutyl phthalate, a liquid) |
| fuels | Teflon; Kapton; Silicone Rubber; Lampwick; Dibutyl Phthalate | llmSample Material: Teflon Sample Material: Kapton: same conditions as 1-4 Sample Material: Silicone Rubber: same conditions as 1-4 Sample Material: Lampwick: same conditions as 1-4 Sample Material: Dibutyl Phthalate: same conditions as 1-4 |
| o2_percent_range | null (not reported) | csv:none |
| pressure_psi_range | null (not reported) | csv:none |
| airflow_cm_s_range | 5; 10 |
|
| gravity | microgravity | rule:gravity_seed |
| pillars | detection | rule:pillar_seed |
| measurements | smoke detectors; video cameras; thermophoretic soot samplers; Transmission Electron microscope (TEM) | llmThe operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke. The operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke. The operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke. After flight, the particulate collected on the thermophoretic probes were analyzed using a Transmission Electron microscope (TEM) to determine primary and aggregate particle dimensions. |
| objective_summary | The investigation aimed to quantify liquid smoke droplet sizes in microgravity and relate droplet size distribution to smoke generation and transport conditions. It also sought to develop a numerical model predicting smoke droplet growth based on pyrolysis rate, vapor properties, and flow environment. | llmOne of the major goals of this investigation was to quantify the sizes that the liquid smoke particulate achieves in low gravity and to relate the droplet size distribution to the smoke generation and smoke transport conditions in the experiment. |
| key_findings | not reported | llm:not_reported |
| earth_applications | Smoke detectors developed from the results can be used in extreme environments on Earth, such as submarines or underwater laboratories, saving lives through accurate smoke detection. | llmThe smoke detectors developed from the results of SAME can also be useful in other extreme environments on Earth, such as submarines or underwater laboratories. |
| tests | 4 rows |
|
| source_urls | https://psi.nasa.gov/physci/repo/data/investigations/PSI-102 | rule:psi_page |
| extraction_confidence | llm_unchecked | extract/checked_ids.txt |