Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-102

SAME

Smoke and Aerosol Measurement Experiment

DetectionSolid fuelIgniterX-extracted, not hand-checked

Where its tests sit

NASA's table for this investigation reports no oxygen value, so none of its 4 test rows can be placed on the chart of the evidence. This is itself a gap: the oxygen level of these tests is not in PSI.

Key facts

Oxygen tested
Not reported
Pressure tested
Not reported
Airflow tested
5–10 cm/s
Fuel phase
Solid fuel
Gravity
Microgravity
Platform
International Space Station (ISS)
Hardware
Comparitive Soot Diagnostic Hardware
Hardware family
Smoke & dust detectionSmoke-measurement instruments (the SAME instrument was reused by DAFT for dust)
Sample / burner size
Not reported

Objective

The investigation aimed to quantify liquid smoke droplet sizes in microgravity and relate droplet size distribution to smoke generation and transport conditions. It also sought to develop a numerical model predicting smoke droplet growth based on pyrolysis rate, vapor properties, and flow environment.

Key findings

Not reported in PSI text

Earth applications

Smoke detectors developed from the results can be used in extreme environments on Earth, such as submarines or underwater laboratories, saving lives through accurate smoke detection.

Fuels and samples

  • Teflon
  • Kapton
  • Silicone Rubber
  • Lampwick
  • Dibutyl Phthalate

Sensors and measurements

  • smoke detectors
  • video cameras
  • thermophoretic soot samplers
  • Transmission Electron microscope (TEM)

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (3)

  • Air Flow (cm/s) · 2 values, e.g. 5; 10
  • Weight loss rate (mg/min) · 2 values, e.g. 2; 1
  • Aging Duration (minutes) · 2 values, e.g. 1; 20

Same in every test (1)

  • Sample Material · Teflon

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#13 of 2458
0 · 15 · 20 · 14 · 9
Moon base / pressurized rover#12 of 2458
0 · 15 · 20 · 14 · 9
Spacesuit#5 of 2448
0 · 5 · 20 · 14 · 9

Test table (4 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published (4 non-test rows set aside, see Data cleaning). Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Sample #Sample MaterialAir Flow (cm/s)Weight loss rate (mg/min)Aging Duration (minutes)
1Teflon521
2Teflon511
3Teflon5220
4Teflon1021

Data cleaning

What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.

PSI-102_Experimental table_SAME.csv · 8 CSV rows → 4 test rows

Set aside (4)

  • row 5 listed as 'same conditions' but no measurements reported5 | Kapton: same conditions as 1-4
  • row 6 listed as 'same conditions' but no measurements reported6 | Silicone Rubber: same conditions as 1-4
  • row 7 listed as 'same conditions' but no measurements reported7 | Lampwick: same conditions as 1-4
  • row 8 listed as 'same conditions' but no measurements reported8 | Dibutyl Phthalate: same conditions as 1-4
Where this came from(source of every field)
FieldValueSource
psi_idPSI-102json:accession
acronymSAMEjson:investigationAcronym
titleSmoke and Aerosol Measurement Experimentjson:title
doi10.60555/gd4k-8h62json:doi
platformInternational Space Station (ISS)json:flightProgram
hardwareComparitive Soot Diagnostic Hardwarejson:experimentHardware
fuel_phasesolid
override
json:approach - "The measurements were made using smoke generated by overheated spacecraft materials" (samples in the SAME table: Kapton, Teflon, silicone rubber, lampwick; also dibutyl phthalate, a liquid)
fuelsTeflon; Kapton; Silicone Rubber; Lampwick; Dibutyl Phthalate
llm
Sample Material: Teflon
Sample Material: Kapton: same conditions as 1-4
Sample Material: Silicone Rubber: same conditions as 1-4
Sample Material: Lampwick: same conditions as 1-4
Sample Material: Dibutyl Phthalate: same conditions as 1-4
o2_percent_rangenull (not reported)csv:none
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_range5; 10
  • csv:PSI-102_Experimental table_SAME.csv:Air Flow (cm/s)
gravitymicrogravityrule:gravity_seed
pillarsdetectionrule:pillar_seed
measurementssmoke detectors; video cameras; thermophoretic soot samplers; Transmission Electron microscope (TEM)
llm
The operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke.
The operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke.
The operator then ran the self diagnostic procedures on the two smoke detectors and activated the video cameras, turned on the igniter for a predefined period of time (15 to 60 seconds), and initiated the thermophoretic soot samplers to sample the smoke.
After flight, the particulate collected on the thermophoretic probes were analyzed using a Transmission Electron microscope (TEM) to determine primary and aggregate particle dimensions.
objective_summaryThe investigation aimed to quantify liquid smoke droplet sizes in microgravity and relate droplet size distribution to smoke generation and transport conditions. It also sought to develop a numerical model predicting smoke droplet growth based on pyrolysis rate, vapor properties, and flow environment.
llm
One of the major goals of this investigation was to quantify the sizes that the liquid smoke particulate achieves in low gravity and to relate the droplet size distribution to the smoke generation and smoke transport conditions in the experiment.
key_findingsnot reported
llm:not_reported
earth_applicationsSmoke detectors developed from the results can be used in extreme environments on Earth, such as submarines or underwater laboratories, saving lives through accurate smoke detection.
llm
The smoke detectors developed from the results of SAME can also be useful in other extreme environments on Earth, such as submarines or underwater laboratories.
tests4 rows
  • csv:PSI-102_Experimental table_SAME.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-102rule:psi_page
extraction_confidencellm_uncheckedextract/checked_ids.txt