Skip to content
Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-21

ACME CLD Flame

Advanced Combustion via Microgravity Experiments / Coflow Laminar Diffusion Flame

PreventionGaseous fuelIgniterX-extracted, not hand-checked

Where its tests sit

NASA's table for this investigation reports no oxygen value, so none of its 32 test rows can be placed on the chart of the evidence. This is itself a gap: the oxygen level of these tests is not in PSI.

Key facts

Oxygen tested
Not reported
Pressure tested
Not reported
Airflow tested
Not reported
Fuel phase
Gaseous fuel
Gravity
Microgravity
Platform
International Space Station (ISS)
Hardware
Combustion Integrated Rack (CIR), ACME
Hardware family
ACME gas flamesModular ACME hardware in the Combustion Integrated Rack (CIR)
Sample / burner size
Not reported

Objective

The investigation aims to gather experimental data on methane and ethylene diffusion flames to test and improve computational models at extremes of fuel dilution. It focuses on characterizing flame shape, extinction limits, temperatures, and sooting behavior in microgravity.

Key findings

Not reported in PSI text

Earth applications

Understanding the factors affecting extinction in diffusion flames supports fire suppression and improves engine efficiency.

Fuels and samples

  • methane
  • ethylene

Sensors and measurements

  • flame chemiluminescence
  • soot luminosity
  • laser extinction
  • thin-filament pyrometry

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (6)

  • Test Type · 3 values, e.g. Methane based test; Ethylene based test; Improved coflow tests
  • Fuel MFC · 2 values, e.g. 0.1; 0.2
  • N2 MFC · 4 values, e.g. 0.1; 0.05; 0.02
  • Fuel Bottle · 30 values, e.g. 40% CH4; 40% CH5; 40% CH6
  • Fuel conc. Range · 18 values, e.g. 30%-40%; 40%; 25%-40%
  • Flames ignited · 15 values, e.g. 10; 5; 8

Same in every test (1)

  • Notes · Test Day - includes the year as the first two digits followed by the 3-digit day of the year (where any late-hour transition to the next day is neglected). MFC - identifies the maximum flow rate of the specified ACME Mass Flow Controller (MFC) in slpm on a nitrogen basis. Fuel conc. - (as diluted with nitrogen on a volume basis) was varied between tests and sometimes during tests where the listing here accounts for both. However, it does not account for extinction that sometimes occurred before the flame fully reached the lowest concentration. Flames ignited is the number ignited on that test day. (31 blank)

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#19 of 2429
0 · 0 · 6 · 14 · 9
Moon base / pressurized rover#19 of 2429
0 · 0 · 6 · 14 · 9
Spacesuit#15 of 2429
0 · 0 · 6 · 14 · 9

Test table (32 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published. Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Test TypeTest DayFuel MFCN2 MFCFuel BottleFuel conc. RangeFlames ignitedNotes
Methane based test173190.10.140% CH430%-40%10Test Day - includes the year as the first two digits followed by the 3-digit day of the year (where any late-hour transition to the next day is neglected). MFC - identifies the maximum flow rate of the specified ACME Mass Flow Controller (MFC) in slpm on a nitrogen basis. Fuel conc. - (as diluted with nitrogen on a volume basis) was varied between tests and sometimes during tests where the listing here accounts for both. However, it does not account for extinction that sometimes occurred before the flame fully reached the lowest concentration. Flames ignited is the number ignited on that test day.
Methane based test173240.10.140% CH530%-40%5
Methane based test173420.10.140% CH640%8
Methane based test173560.10.140% CH730%-40%3
Methane based test180030.10.140% CH825%-40%9
Methane based test180050.10.140% CH930%-40%7
Methane based test180080.10.140% CH1025%-40%8
Methane based test180110.10.140% CH1125%-40%14
Methane based test180220.10.140% CH1230%-40%3
Methane based test180260.10.140% CH1325%-40%16
Methane based test180320.10.140% CH1430%-40%13
Methane based test180390.10.05100% CH450%-80%8
Methane based test180430.10.05100% CH550%-100%10
Methane based test180530.10.02100% CH630%-40%16
Ethylene based test181450.20.1100% C2H480%-100%3
Ethylene based test181510.20.1100% C2H5100%2
Ethylene based test181770.20.1100% C2H680%-100%9
Ethylene based test181860.20.1100% C2H760%-100%14
Ethylene based test181920.20.1100% C2H850%-60%10
Ethylene based test181990.20.1100% C2H940%-100%16
Ethylene based test182140.20.05100% C2H10100%13
Ethylene based test182180.20.05100% C2H1180%18
Ethylene based test182350.20.150% C2H450%16
Ethylene based test182390.20.150% C2H540%14
Ethylene based test182410.10.250% C2H610%-20%6
Ethylene based test182490.10.250% C2H710%-30%12
Ethylene based test182530.10.250% C2H815%-30%14
Ethylene based test182570.10.250% C2H915%-20%15
Improved coflow tests210410.20.230% C2H40%-30%9
Improved coflow tests210460.20.230% C2H515%-20%16
Improved coflow tests210500.20.240% CH420%-40%16
Improved coflow tests210620.20.240% CH530%-40%11

Data cleaning

What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.

PSI-21_Experimental table_CLD Flame.csv · 32 CSV rows → 32 test rows

Flagged in kept rows (26)

  • row 2 Fuel Bottle '40% CH5' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 3 Fuel Bottle '40% CH6' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 4 Fuel Bottle '40% CH7' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 5 Fuel Bottle '40% CH8' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 6 Fuel Bottle '40% CH9' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 7 Fuel Bottle '40% CH10' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 8 Fuel Bottle '40% CH11' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 9 Fuel Bottle '40% CH12' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 10 Fuel Bottle '40% CH13' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 11 Fuel Bottle '40% CH14' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'
  • row 13 Fuel Bottle '100% CH5' is a spreadsheet fill-series artifact (no such gas); read as '100% CH4'
  • row 14 Fuel Bottle '100% CH6' is a spreadsheet fill-series artifact (no such gas); read as '100% CH4'
  • row 16 Fuel Bottle '100% C2H5' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 17 Fuel Bottle '100% C2H6' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 18 Fuel Bottle '100% C2H7' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 19 Fuel Bottle '100% C2H8' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 20 Fuel Bottle '100% C2H9' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 21 Fuel Bottle '100% C2H10' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 22 Fuel Bottle '100% C2H11' is a spreadsheet fill-series artifact (no such gas); read as '100% C2H4'
  • row 24 Fuel Bottle '50% C2H5' is a spreadsheet fill-series artifact (no such gas); read as '50% C2H4'
  • row 25 Fuel Bottle '50% C2H6' is a spreadsheet fill-series artifact (no such gas); read as '50% C2H4'
  • row 26 Fuel Bottle '50% C2H7' is a spreadsheet fill-series artifact (no such gas); read as '50% C2H4'
  • row 27 Fuel Bottle '50% C2H8' is a spreadsheet fill-series artifact (no such gas); read as '50% C2H4'
  • row 28 Fuel Bottle '50% C2H9' is a spreadsheet fill-series artifact (no such gas); read as '50% C2H4'
  • row 30 Fuel Bottle '30% C2H5' is a spreadsheet fill-series artifact (no such gas); read as '30% C2H4'
  • row 32 Fuel Bottle '40% CH5' is a spreadsheet fill-series artifact (no such gas); read as '40% CH4'

NASA's notes in this table

  • Test Day - includes the year as the first two digits followed by the 3-digit day of the year (where any late-hour transition to the next day is neglected). MFC - identifies the maximum flow rate of the specified ACME Mass Flow Controller (MFC) in slpm on a nitrogen basis. Fuel conc. - (as diluted with nitrogen on a volume basis) was varied between tests and sometimes during tests where the listing here accounts for both. However, it does not account for extinction that sometimes occurred before the flame fully reached the lowest concentration. Flames ignited is the number ignited on that test day.
Where this came from(source of every field)
FieldValueSource
psi_idPSI-21json:accession
acronymACME CLD Flamejson:investigationAcronym
titleAdvanced Combustion via Microgravity Experiments / Coflow Laminar Diffusion Flamejson:title
doi10.60555/23e1-9950json:doi
platformInternational Space Station (ISS)json:flightProgram
hardwareCombustion Integrated Rack (CIR), ACMEjson:experimentHardware
fuel_phasegasrule:fuel_phase_seed
fuelsmethane; ethylene
llm
Fuel Bottle: 40% CH4
Fuel Bottle: 100% C2H4
o2_percent_rangenull (not reported)csv:none
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_rangenull (not reported)csv:none
gravitymicrogravityrule:gravity_seed
pillarspreventionrule:pillar_seed
measurementsflame chemiluminescence; soot luminosity; laser extinction; thin-filament pyrometry
llm
For the more dilute flames, measurements will be made of flame chemiluminesence of OH* and CH* to observe variations in lift-off height and flame shape as extinction limits are approached.
The sooting tendencies of the more fuel-rich flames will be investigated using soot luminosity and laser extinction measurements to determine soot temperatures and soot volume fractions.
The sooting tendencies of the more fuel-rich flames will be investigated using soot luminosity and laser extinction measurements to determine soot temperatures and soot volume fractions.
Flame temperatures in non-sooting regions will be measured using thin-filament pyrometry.
objective_summaryThe investigation aims to gather experimental data on methane and ethylene diffusion flames to test and improve computational models at extremes of fuel dilution. It focuses on characterizing flame shape, extinction limits, temperatures, and sooting behavior in microgravity.
llm
In order to provide the experimental data needed to allow rigorous testing of computational models at the extremes of the fuel dilution spectrum, we have the following objectives:
key_findingsnot reported
llm:not_reported
earth_applicationsUnderstanding the factors affecting extinction in diffusion flames supports fire suppression and improves engine efficiency.
llm
In addition, an understanding of those factors that affect flame extinction in diffusion flames is critical in the suppression of fires and in improving engine efficiency.
tests32 rows
  • csv:PSI-21_Experimental table_CLD Flame.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-21rule:psi_page
extraction_confidencellm_uncheckedextract/checked_ids.txt