Skip to content
Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-22

ACME E-FIELD Flames

Advanced Combustion via Microgravity Experiments Electric-Field Effects on Laminar Diffusion Flames

PreventionGaseous fuelIgniterX-extracted, not hand-checked

Where its tests sit

NASA's table for this investigation reports no oxygen value, so none of its 20 test rows can be placed on the chart of the evidence. This is itself a gap: the oxygen level of these tests is not in PSI.

Key facts

Oxygen tested
Not reported
Pressure tested
Not reported
Airflow tested
Not reported
Fuel phase
Gaseous fuel
Gravity
Partial gravity (mimicked by electric field)
Platform
International Space Station (ISS)
Hardware
Combustion Integrated Rack (CIR), ACME
Hardware family
ACME gas flamesModular ACME hardware in the Combustion Integrated Rack (CIR)
Sample / burner size
Not reported

Objective

The investigation aims to better understand the relationship between electric field voltage and chemi-ion current, analyze flame dynamic responses to electric field changes, evaluate soot formation, and characterize stabilized near-limit lifted flames.

Key findings

Recording voltage-current curves assessed the relationship between electric field strength and chemi-ion current, revealing ion-driven convection effects.

Earth applications

Using electric fields to control flames can reduce harmful pollutant production and fuel consumption, enabling more efficient terrestrial combustion.

Fuels and samples

  • 100% CH4
  • 40% CH4
  • 100% C2H4
  • 30% C2H4

Sensors and measurements

  • ion current
  • flame response time
  • voltage-current curves
  • high-resolution cameras
  • spectral imaging with filters
  • thermopile detectors

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (6)

  • Test Type · 2 values, e.g. First round of tests with coflow burner; Second round of tests with gas-jet burner
  • Mesh Polarity · 2 values, e.g. negative; positive
  • Fuel Bottle · 4 values, e.g. 100% CH4; 40% CH4; 100% C2H4
  • Fuel Conc · 6 values, e.g. 100%; 70%; 40%
  • Flames Ignited · 7 values, e.g. 10; 8; 11
  • Notes · 3 values, e.g. Test day is formatted YYDDD where YY identifies year and DDD identifies day of year (GMT).; Mesh polarity refers to the polarity of the high-voltage power supply and the copper electrode relative to the burner.; Flames Ignited is the number ignited on that day (neglecting the day change on ISS). (17 blank)

Same in every test (0)

No column held the same value in every test.

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#17 of 2430
0 · 0 · 6 · 14 · 10
Moon base / pressurized rover#17 of 2430
0 · 0 · 6 · 14 · 10
Spacesuit#13 of 2430
0 · 0 · 6 · 14 · 10

Test table (20 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published (12 non-test rows set aside, see Data cleaning). Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Test TypeTest DayYearMonthDateMesh PolarityFuel BottleFuel ConcFlames IgnitedNotes
First round of tests with coflow burner180732018314negative100% CH4100%10Test day is formatted YYDDD where YY identifies year and DDD identifies day of year (GMT).
First round of tests with coflow burner180782018319negative100% CH470%10Mesh polarity refers to the polarity of the high-voltage power supply and the copper electrode relative to the burner.
First round of tests with coflow burner180802018321negative40% CH440%8Flames Ignited is the number ignited on that day (neglecting the day change on ISS).
First round of tests with coflow burner180872018328negative100% C2H480%10
First round of tests with coflow burner18092201842negative30% C2H430%11
First round of tests with coflow burner18095201845positive30% C2H430%10
First round of tests with coflow burner181022018412positive40% CH440%8
First round of tests with coflow burner181062018416positive40% CH440%13
First round of tests with coflow burner181132018423positive100% CH4100%15
First round of tests with coflow burner181302018510positive100% CH470%13
First round of tests with coflow burner181372018517positive100% C2H480%12
Second round of tests with gas-jet burner182692018926negative40% CH440%11
Second round of tests with gas-jet burner182742018101negative30% C2H430%11
Second round of tests with gas-jet burner182822018109negative100% CH470%13
Second round of tests with gas-jet burner1828520181012negative100% C2H4100%10
Second round of tests with gas-jet burner1829020181017negative100% C2H480%11
Second round of tests with gas-jet burner1829820181025positive40% CH440%9
Second round of tests with gas-jet burner1830220181029positive30% C2H430%10
Second round of tests with gas-jet burner183122018118positive100% CH470%13
Second round of tests with gas-jet burner1831920181115positive100% C2H425%11

Data cleaning

What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.

PSI-22_Experimental table_ACME E-FIELD Flames.csv · 32 CSV rows → 20 test rows

Set aside (12)

  • row 3 note / continuation row with no test identity100% | Fuel Conc. (diluted with nitrogen on a volume basis) was varied between tests, but typically matched the bottle. The list only accounts for flames ignited.
  • row 6 note / continuation row with no test identity100%
  • row 14 note / continuation row with no test identity100%
  • row 18 note / continuation row with no test identity100%
  • row 24 note / continuation row with no test identity100%
  • row 26 note / continuation row with no test identity50%
  • row 27 note / continuation row with no test identity80%
  • row 28 note / continuation row with no test identity100%
  • row 29 exact duplicate of row 25Second round of tests with gas-jet burner | 18319 | 2018 | 11 | 15 | positive | 100% C2H4 | 25% | 11
  • row 30 note / continuation row with no test identity50%
  • row 31 note / continuation row with no test identity80%
  • row 32 note / continuation row with no test identity100%

NASA's notes in this table

  • 100% Fuel Conc. (diluted with nitrogen on a volume basis) was varied between tests, but typically matched the bottle. The list only accounts for flames ignited.
  • 100%
  • 100%
  • 100%
  • 100%
  • 50%
  • 80%
  • 100%
  • 50%
  • 80%
  • 100%
  • Test day is formatted YYDDD where YY identifies year and DDD identifies day of year (GMT).
  • Mesh polarity refers to the polarity of the high-voltage power supply and the copper electrode relative to the burner.
  • Flames Ignited is the number ignited on that day (neglecting the day change on ISS).
Where this came from(source of every field)
FieldValueSource
psi_idPSI-22json:accession
acronymACME E-FIELD Flamesjson:investigationAcronym
titleAdvanced Combustion via Microgravity Experiments Electric-Field Effects on Laminar Diffusion Flamesjson:title
doi10.60555/se5a-8c73json:doi
platformInternational Space Station (ISS)json:flightProgram
hardwareCombustion Integrated Rack (CIR), ACMEjson:experimentHardware
fuel_phasegasrule:fuel_phase_seed
fuels100% CH4; 40% CH4; 100% C2H4; 30% C2H4
llm
Fuel Bottle: 100% CH4
Fuel Bottle: 40% CH4
Fuel Bottle: 100% C2H4
Fuel Bottle: 30% C2H4
o2_percent_rangenull (not reported)csv:none
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_rangenull (not reported)csv:none
gravitypartial_mimicrule:gravity_seed (mimics partial gravity)
pillarspreventionrule:pillar_seed
measurementsion current; flame response time; voltage-current curves; high-resolution cameras; spectral imaging with filters; thermopile detectors
llm
Measurements, as a function of the field strength and fuel, are taken of the ion current through the flame and the flame’s response time to electric forcing.
Measurements, as a function of the field strength and fuel, are taken of the ion current through the flame and the flame’s response time to electric forcing.
Voltage-current curves were recorded to assess the relationship between electric field strength and chemi-ion current, revealing ion-driven convection effects.
High-resolution cameras captured flame shape, luminosity, and soot distribution.
Spectral imaging with filters measures chemiluminescent emissions and soot volume fraction.
There were thermopile detectors to measure flame radiant emissions.
objective_summaryThe investigation aims to better understand the relationship between electric field voltage and chemi-ion current, analyze flame dynamic responses to electric field changes, evaluate soot formation, and characterize stabilized near-limit lifted flames.
llm
The objective of this investigation is to better understand the relationship between electric field voltage and chemi-ion current, analyze the dynamic response of flames to electric field changes, evaluate soot formation, and characterize stabilized near-limit lifted flames.
key_findingsRecording voltage-current curves assessed the relationship between electric field strength and chemi-ion current, revealing ion-driven convection effects.
llm
Voltage-current curves were recorded to assess the relationship between electric field strength and chemi-ion current, revealing ion-driven convection effects.
earth_applicationsUsing electric fields to control flames can reduce harmful pollutant production and fuel consumption, enabling more efficient terrestrial combustion.
llm
The use of electric fields to control flames can reduce the production of harmful pollutants in practical terrestrial combustion.
tests20 rows
  • csv:PSI-22_Experimental table_ACME E-FIELD Flames.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-22rule:psi_page
extraction_confidencellm_uncheckedextract/checked_ids.txt