Skip to content
Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-98

SAFFIRE-I

Spacecraft Fire Safety Experiment-I

PreventionSolid fuelIgniterX-extracted, not hand-checked

Where its tests sit

This investigation's own test rows on the chart of the evidence; the red frame is the Moon base / rover region. Switch habitats on the dashboard.

Oxygen, % by volume →

no psi reported
0 of 2 NASA test rows report both oxygen and pressure, from 0 investigations. 2 more report oxygen only (bottom strip). 0 report no oxygen at all, so they can't be placed: . See every row

Key facts

Oxygen tested
21.5–21.7 % O₂
Pressure tested
Not reported
Airflow tested
20 cm/s
Fuel phase
Solid fuel
Gravity
Microgravity
Platform
Cygnus resupply vehicle (after it deberthed from the ISS)
Hardware
Saffire 1 enclosure in Cygnus
Hardware family
Large-scale spacecraft firesSaffire enclosure on the Cygnus cargo vehicle, after it left the ISS
Sample / burner size
  • Sample Thickness (cm): 0.37
  • Sample Length (cm): 40.6
  • Sample Width (cm): 94

Objective

The SAFFIRE-I experiment aims to evaluate how quickly large-scale fires spread in low gravity. It also investigates microgravity flammability limits compared to normal-gravity material screening standards.

Key findings

Not reported in PSI text

Earth applications

Understanding fire behavior in small, enclosed spacecraft environments aids fire safety and prevention strategies on Earth, particularly within confined spaces like mines, airplanes, and submarines.

Fuels and samples

  • SIBAL fabric, 0.94 m x 0.4 m, 0.37 cm thick

Sensors and measurements

  • cameras
  • thermocouples
  • radiometers
  • solid state sensors
  • anemometer

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (3)

  • Percent O2 · 2 values, e.g. 21.5 - 21.7; ~ 21.5
  • Burn Time (s) · 2 values, e.g. 420; 70
  • Flow Direction · 2 values, e.g. Concurrent; Opposed

Same in every test (7)

  • Material · SIBAL Fabric
  • Sample Thickness (cm) · 0.37
  • Sample Length (cm) · 40.6
  • Sample Width (cm) · 94
  • Air Flow (cm/s) · 20
  • Ignition Power (W) · 182
  • Ignition Time (s) · 8

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#1 of 2493.4
34.4 · 15 · 20 · 14 · 10
Moon base / pressurized rover#2 of 2484.3
25.3 · 15 · 20 · 14 · 10
Spacesuit#1 of 2449
0 · 5 · 20 · 14 · 10

Test table (2 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published (2 non-test rows set aside, see Data cleaning). Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Sample NumberMaterialSample Thickness (cm)Sample Length (cm)Sample Width (cm)Air Flow (cm/s)Percent O2Ignition Power (W)Ignition Time (s)Burn Time (s)Flow DirectionCamera 1Camera 2
S1SIBAL Fabric0.3740.6942021.5 - 21.71828420ConcurrentS1C1S1C2
S2SIBAL Fabric0.3740.69420~ 21.5182870OpposedS2C1S2C2

Data cleaning

What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.

PSI-98_Experimental table_SAFFIRE-1.csv · 4 CSV rows → 2 test rows

Set aside (2)

  • row 3 flow-visualization reference with no test dataF1C1/F1C2 | Pre-test flow visulation data for sample 1
  • row 4 flow-visualization reference with no test dataF2C1/F2C2 | Pre-test flow visulation data for sample 2
Where this came from(source of every field)
FieldValueSource
psi_idPSI-98json:accession
acronymSAFFIRE-Ijson:investigationAcronym
titleSpacecraft Fire Safety Experiment-Ijson:title
doi10.60555/0t15-1z43json:doi
platformCygnus resupply vehicle (after it deberthed from the ISS)
override
json:approach - "The Saffire-1 experiments was performed on the Orbital Science’s Cygnus resupply vehicle after it deberthed from the ISS."
hardwareSaffire 1 enclosure in Cygnusjson:experimentHardware
fuel_phasesolidrule:fuel_phase_seed
fuelsSIBAL fabric, 0.94 m x 0.4 m, 0.37 cm thick
llm
Material: SIBAL Fabric
o2_percent_range21.5; 21.7
  • csv:PSI-98_Experimental table_SAFFIRE-1.csv:Percent O2
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_range20; 20
  • csv:PSI-98_Experimental table_SAFFIRE-1.csv:Air Flow (cm/s)
gravitymicrogravityrule:gravity_seed
pillarspreventionrule:pillar_seed
measurementscameras; thermocouples; radiometers; solid state sensors; anemometer
llm
Once the sample was ignited flame images were captured using two cameras.
In addition, thermocouples provided flow, flame, and plume temperatures
two radiometers recorded flame radiation
solid state sensors were used to measure pressure, CO2 and O2 mole faction
two anemometer tracked flow velocity.
objective_summaryThe SAFFIRE-I experiment aims to evaluate how quickly large-scale fires spread in low gravity. It also investigates microgravity flammability limits compared to normal-gravity material screening standards.
llm
(1) determine how rapidly a large scale fire grows in low-gravity
key_findingsnot reported
llm:not_reported
earth_applicationsUnderstanding fire behavior in small, enclosed spacecraft environments aids fire safety and prevention strategies on Earth, particularly within confined spaces like mines, airplanes, and submarines.
llm
Studying fire in small, sealed environments such as the Cygnus cargo supply vehicle benefits fire safety and prevention efforts on Earth, including inside mines, airplanes, or submarines.
tests2 rows
  • csv:PSI-98_Experimental table_SAFFIRE-1.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-98rule:psi_page
extraction_confidencellm_uncheckedextract/checked_ids.txt