Skip to content
Flame in FreefallNASA microgravity fire evidence
Back to dashboard

PSI-99

SAFFIRE-II

Spacecraft Fire Experiment-II

PreventionSolid fuelIgniterX-extracted, not hand-checked

Where its tests sit

This investigation's own test rows on the chart of the evidence; the red frame is the Moon base / rover region. Switch habitats on the dashboard.

Oxygen, % by volume →

no psi reported
0 of 9 NASA test rows report both oxygen and pressure, from 0 investigations. 9 more report oxygen only (bottom strip). 0 report no oxygen at all, so they can't be placed: . See every row

Key facts

Oxygen tested
21.5–22.1 % O₂
Pressure tested
Not reported
Airflow tested
20 cm/s
Fuel phase
Solid fuel
Gravity
Microgravity
Platform
Cygnus Spacecraft
Hardware
Cygnus Pressurized Cargo Module, SAFFIRE
Hardware family
Large-scale spacecraft firesSaffire enclosure on the Cygnus cargo vehicle, after it left the ISS
Sample / burner size
  • Samle Thickness: 0.27 mm, 0.61 mm, 1.03 mm, 037 mm +3 more
  • Sample Length: 29 cm, 5 and 24 cm
  • Sample Width (cm): 5 cm

Objective

The SAFFIRE-II investigation aims to determine how rapidly a large-scale fire grows in low gravity and to evaluate low-g flammability limits relative to NASA's terrestrial screening tests.

Key findings

Cotton-Fiberglass (SIBAL) burned for 145 seconds in low gravity with a 29 cm burn length and 2.1 mm/s spread rate, whereas silicone samples had insignificant burn times and near-zero microgravity burn lengths.

Earth applications

Fire studies in small, sealed environments like Cygnus benefit terrestrial fire safety and prevention efforts in confined spaces such as mines, airplanes, or submarines.

Fuels and samples

  • Silicone
  • Cotton-Fiberglass (SIBAL)
  • PMMA & Nomex
  • PMMA

Sensors and measurements

  • cameras
  • thermocouples
  • radiometers
  • solid state sensors
  • anemometer

How the tests differed

What changed from one test to the next, and what stayed fixed, read straight from NASA's test table. Dates, times and test numbers are left out.

Varied between tests (12)

  • Material · 4 values, e.g. Silicone; Cotton-Fiberglass (SIBAL); PMMA & Nomex (2 blank)
  • Samle Thickness · 7 values, e.g. 0.27 mm; 0.61 mm; 1.03 mm
  • Sample Length · 2 values, e.g. 29 cm; 5 and 24 cm
  • Percent O2 (Note 1) · 4 values, e.g. ~ 21.5; ~ 22.1; 22.1 to 22.0
  • Ignition Power (W) · 2 values, e.g. 80 W; 97 W
  • Ignition Time (s) · 2 values, e.g. 9.2 s; 30 s
  • Burn Time (s) · 6 values, e.g. Insignificant; 145 s; 115 s
  • Flow Direction · 2 values, e.g. Concurrent; Opposed
  • ?-g Burn Length · 5 values, e.g. ~ 0; 29 cm; 5 cm & 0 (note 2)
  • ?-g Spread Length · 5 values, e.g. n/a; 2.1 mm/s; 2.6 mm/s
  • 1-g Burn Length · 4 values, e.g. Complete; 7.6 cm; ~ 0
  • 1-g Spread Rate · 5 values, e.g. Acceleratory; 1.2 mm/s; n/a

Same in every test (2)

  • Sample Width (cm) · 5 cm
  • Air Flow (cm/s) · 20 cm/s

Score in each scenario

Focus: all pillars, each scenario's default ventilation. Full reasons are in the dashboard table.

ScenarioRankScoreA · B · C · D · E
ISS cabin#2 of 2493.4
34.4 · 15 · 20 · 14 · 10
Moon base / pressurized rover#1 of 2484.8
25.8 · 15 · 20 · 14 · 10
Spacesuit#2 of 2449
0 · 5 · 20 · 14 · 10

Test table (9 rows)

Test rows from NASA's experimental-table CSV, every cell exactly as published (6 non-test rows set aside, see Data cleaning). Download as CSV · Compare with all tests in the Data Explorer

Experimental table

Sample NumberMaterialSamle ThicknessSample LengthSample Width (cm)Air Flow (cm/s)Percent O2 (Note 1)Ignition Power (W)Ignition Time (s)Burn Time (s)Flow Direction?-g Burn Length?-g Spread Length1-g Burn Length1-g Spread RateCamera 1Camera 2
2-1Silicone0.27 mm29 cm5 cm20 cm/s~ 21.580 W9.2 sInsignificantConcurrent~ 0n/aCompleteAcceleratoryS1C1S1C2
2-2Silicone0.61 mm29 cm5 cm20 cm/s~ 22.180 W9.2 sInsignificantConcurrent~ 0n/a7.6 cm1.2 mm/sn/aS2C2
2-3Silicone1.03 mm29 cm5 cm20 cm/s~ 22.180 W9.2 sInsignificantConcurrent~ 0n/a~ 0n/aS3C2
2-4Silicone037 mm29 cm5 cm20 cm/s~ 22.180 W9.2 sInsignificantOpposed~ 0n/aComplete0.6 mm/sS4C1S4C1
2-5Cotton-Fiberglass (SIBAL)037 mm29 cm5 cm20 cm/s~ 22.180 W9.2 s145 sConcurrent29 cm2.1 mm/sCompleteAcceleratoryS5C1S5C2
2-6037 mm29 cm5 cm20 cm/s~ 22.180 W9.2 s115 sConcurrent29 cm2.6 mm/sCompleteAcceleratoryS6C1S56C2
2-7PMMA & Nomex0.85 and 0.37 mm5 and 24 cm5 cm20 cm/s~ 22.180 W9.2 s140 sConcurrent5 cm & 0 (note 2)n/a (Nomex)~ 0 (Nomex)n/a (Nomex)S7C1n/a
2-8PMMASee Fig. 529 cm5 cm20 cm/s22.1 to 22.097 W30 s600 sConcurrent~ 10 cm (note 3)Note 4CompleteAcceleratoryS8C1n/a
2-91 cm29 cm5 cm20 cm/s22.0 to 21.997 W30 s900 sConcurrent~ 10 cm (note 4)Note 4CompleteAcceleratoryS9C1n/a

Data cleaning

What the row-by-row check of NASA's CSV found. Rows that are not tests are set aside (not deleted from the source); problems in kept rows are flagged, never silently fixed.

PSI-99_Experimental table_SAFFIRE-2.csv · 15 CSV rows → 9 test rows

Set aside (6)

  • row 10 flow-visualization reference with no test dataF1C1/F1C2 | Pre-test flow visulation data for sample 2-1
  • row 11 flow-visualization reference with no test dataF2C1/F2C2 | Pre-test flow visulation data for sample 2-2
  • row 12 footnote line, not a test
  • row 13 footnote line, not a test
  • row 14 footnote line, not a test
  • row 15 footnote line, not a test

Flagged in kept rows (6)

  • row 4 Samle Thickness '037 mm' looks like a typo for 0.37 mm (source value kept, not converted)
  • row 5 Samle Thickness '037 mm' looks like a typo for 0.37 mm (source value kept, not converted)
  • row 6 Samle Thickness '037 mm' looks like a typo for 0.37 mm (source value kept, not converted); Material is blank in the source
  • row 7 Samle Thickness '0.85 and 0.37 mm' is a two-layer sample, not one thickness
  • row 8 Samle Thickness refers to a figure that is not in the PSI table
  • row 9 Material is blank in the source

NASA's notes in this table

  • Note 1 Derived from measured CO2 production and referenced to initial O2 concentration reported by ISS.
  • Note 2 The PMMA portion was completely consumed but the Nomex was not ignited.
  • Note 3 This is the length of fuel with significant visible damage.
  • Note 4 The flames remain anchored at the base of the sample which has a very slow regression rate (0.01 to 0.04 mm/s)
Where this came from(source of every field)
FieldValueSource
psi_idPSI-99json:accession
acronymSAFFIRE-IIjson:investigationAcronym
titleSpacecraft Fire Experiment-IIjson:title
doi10.60555/2chp-m469json:doi
platformCygnus Spacecraftjson:flightProgram
hardwareCygnus Pressurized Cargo Module, SAFFIREjson:experimentHardware
fuel_phasesolidrule:fuel_phase_seed
fuelsSilicone; Cotton-Fiberglass (SIBAL); PMMA & Nomex; PMMA
llm
Material: Silicone
Material: Cotton-Fiberglass (SIBAL)
Material: PMMA & Nomex
Material: PMMA
o2_percent_range21.5; 22.1
  • csv:PSI-99_Experimental table_SAFFIRE-2.csv:Percent O2 (Note 1)
pressure_psi_rangenull (not reported)csv:none
airflow_cm_s_range20; 20
  • csv:PSI-99_Experimental table_SAFFIRE-2.csv:Air Flow (cm/s)
gravitymicrogravityrule:gravity_seed
pillarspreventionrule:pillar_seed
measurementscameras; thermocouples; radiometers; solid state sensors; anemometer
llm
Once the sample was ignited flame images were captured using two cameras.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
In addition, thermocouples provided flow, flame, and plume temperatures, two radiometers recorded flame radiation, solid state sensors were used to measure pressure, CO2 and O2 mole faction, and two anemometer tracked flow velocity.
objective_summary The SAFFIRE-II investigation aims to determine how rapidly a large-scale fire grows in low gravity and to evaluate low-g flammability limits relative to NASA's terrestrial screening tests.
llm
The objectives of SAFFIRE-II are to determine how rapidly a large scale fire grows in low-gravity and to investigate the low-g flammability limits compared to those obtained in NASA’s normal gravity material flammability screening test.
key_findingsCotton-Fiberglass (SIBAL) burned for 145 seconds in low gravity with a 29 cm burn length and 2.1 mm/s spread rate, whereas silicone samples had insignificant burn times and near-zero microgravity burn lengths.
llm
2-5, Cotton-Fiberglass (SIBAL), 037 mm, 29 cm, 5 cm, 20 cm/s, ~ 22.1, 80 W, 9.2 s, 145 s, Concurrent, 29 cm, 2.1 mm/s, Complete, Acceleratory, S5C1, S5C2
earth_applicationsFire studies in small, sealed environments like Cygnus benefit terrestrial fire safety and prevention efforts in confined spaces such as mines, airplanes, or submarines.
llm
Studying fire in small, sealed environments such as the Cygnus cargo supply vehicle benefits fire safety and prevention efforts on Earth, including inside mines, airplanes, or submarines.
tests9 rows
  • csv:PSI-99_Experimental table_SAFFIRE-2.csv
source_urlshttps://psi.nasa.gov/physci/repo/data/investigations/PSI-99rule:psi_page
extraction_confidencellm_uncheckedextract/checked_ids.txt